Phoenix-986AA
The Phoenix-986AAS is an easy-to-use Atomic Absorption Spectrophotometer dedicated to the laboratories that are after practical operation rather than extravagant sophistication which may never be required to the extent of 70% sometimes. What we are offering here is a low-cost alternative where no efforts were spared to provide high precision and ease of use in a simple instrument which can fit in every budget.
Fitted with a motorised flame/furnace switchover at a press of a key, it uses a personal computer to control via a dedicated applications software the instrument and relevant accessories.
The automatic 8-lamp turret provides a multi-sequential AA analysis whereas eight different elements may be selected at one time with their respective measurement parameters and then loaded automatically in the respective order provided by the operator. The settings and adjustments of the instrument's conditions for measurement are completed automatically.
Two Background Correction modes are offered to the user's choice. The self-reversion mode that can be carried out over the entire wavelength range using the same light of a Hollow Cathode Lamp but with a different lamp current and the D2 Lamp Background Correction mode which is ideal for high sensitivity analyses.
An automatic temperature control is secured during graphite furnace measurements. Up to 9 heating steps are allowed with 3 choices of ramp, ladder and full-power heating. All signal and temperature curves may be stored for future re- call by the operator.
A complete data report of single-element or multi-element measurements is offered for display and print-out. The spectra of element lamps, standard curves, signal curves, operating parameters and operator's own-defined texts may be displayed and printed out upon demand.
SPECIFICATIONS:
- Wavelength Range: 190 - 900nm
- Monochromator: Czerny-Turner configuration
- Spectral Bandwidth: 0.1, 0.2, 0.5, 1.0 and 2.0 nm with automatic changeover in 5 steps.
- Wavelength Accuracy: +/- 0.3nm
- Wavelength Repeatability: 0.2nm
- Resolution: Over 0.3nm
- Baseline Stability: 0.005A/30 Min
FLAME MODE:
- Sensitivity: Cu 5ug/ml >0.850 Abs.
- Burner Head: Titanium Alloy Burner
- Nebuliser: High-Efficiency glass nebuliser
- Atomisation Chamber: Corrosion resistant material
- Position Adjustment: Automatic Changeover of flame and furnace, Automatic setting of optimum height for flame burner and automatic ignition of mixing air-acetylene gas with protection control.
GRAPHITE FURNACE MODE:
- Character Value (Cd): 0.8 Pg
- Temperature Range: Ambient to 2650 Deg.C.
- Heating: Voltage Feedback control when drying and ashing, optical temperature control when atomising
- Heating programme: Up to 9 steps with choices of ramp, ladder and full-power heating.
BACKGROUND CORRECTION:
- Deuterium Lamp Background Correction: 1.0 Abs
- Self-Reversal Background Correction: 3.0 Abs
DATA PROCESSING & MANAGEMENT:
- Analytical Method: Flame, Graphite furnace and hydride
- Determination Method: Calibration Curves (1-3 order), standard addition method
- Repeating Times: 1-20 times with calculations of average value, SD and RSD
- Results Printout: Output of Parameters, data, spectra and curves.
MAINFRAME
- Light Source: Automatic 8 Lamp-Turret, 2 lamps simultaeously lit with one pre-heat.
- Power Supply: 220V/50Hz Three-phase AC, 200W Mainframe, 5000W for graphite Furnace.
- Size: Mainframe 110 x 50 x 45 cm, 75 Kg.
- Graphite Furnace 50 x 50 x 45 cm, 50 Kg